ACC-99D DECODER

The versatility of the ACC controller grows even more powerful with the addition of the two-wire decoder system. ACC-99D uses two-wire decoders to control up to 99 stations without giving up the arsenal of features provided by the ACC. Operating large numbers of valves over long distances, the ACC99D decoder controller takes full advantage of the powerful ACC feature set. Since it’s two-wire powered, it also saves copper wire, simplifies troubleshooting, permits rapid addition of new stations, minimizes trenching, and permits remote sensor monitoring over the two-wire path.

ICD-100, 200, ICD-SEN

Height

: 92 mm

Width

: 38 mm

Depth

: 12.7 mm

ICD-400, 600

Height

: 92 mm

Width

: 46 mm

Depth

: 38 mm

OTHER SPECIFICATIONS

  • Transformer Input: 120/230 VAC, 50/60 Hz, 2A max at 120V, 1A max at 230V.
  • Max AC Current Draw: 120 VAC, 2 Amps; 230 VAC, 1 Amp (max computed with all programs running and optional accessories installed)
  • Transformer output: 24 VAC, 4A, at 120 VAC
    Decoder Line (path) output: 34 V peak-to-peak
    Decoder Power draw: 40 mA per active output
    Solenoid capacity: 2 standard 24 VAC  solenoids per output within 45 m. runs, up to 14 solenoids max simultaneous (includes dual P/MV outputs)
  • Wiring, Decoder to solenoid: 45 m max
  • 6 two-wire output paths to field decoders
  • Two-way confirmation of decoder activation
  • Two-way monitoring of sensor connections (ICD-SEN)Diagnostic LEDs with line status, signal activity, decoder and status.